The refrigeration principle of an open type chiller
Open type chiller is a type of temperature controller, also known as oil heater and chiller refrigeration heater. Therefore, thermal oil, as the introduction of the mold temperature controller, is widely used to help manufacture engineering plastics and plastic products. It is controlled by computer touch and easy to operate, and is highly favored by the public.
An open type chiller is a model temperature machine that uses heat transfer oil as a heat transfer precursor. The open type chiller itself is equipped with a storage tank. During operation, the heat transfer oil enters the system from the storage tank and is pumped into the mold or other temperature controlled buildings through a circulating pump. After coming out of the temperature controlled building, the heat transfer oil returns to the system and circulates back and forth. The heat transfer oil is heated by the heater, and when the medium temperature detected by the temperature sensing probe reaches the set value, the heater stops working. When the temperature is below the set value, the heater works first, and when the temperature reaches the set value, it stops working again. Cloud like cycles come and go.
The advantages of an open type chiller:
1、 Reincarnation unilaterally accepts the continuous shaft high-temperature oil pump, which is characterized by high temperature capability, large head and flow rate, and good consolidation in successive applications; Mechanical pipelines, elbows, flanges, PASS pipelines, pressure gauge pipelines, etc. are all made of carbon steel (No. 20 steel) designated by the country of application. The characteristics of carbon steel, such as rust resistance, oxidation resistance, and high temperature resistance, are commonly used by customers.
The two electric heating cycle system and the electric heating tubes used in open chillers are planned based on the German heating tube design (including surface). The U-shaped tube of the heating tube is made of 304 stainless steel, and the heating wire is made of nickel chromium wire. The addition of powder is high-temperature inlet magnesium oxide, which can ensure the consolidation of the heating element for customers in the later application process.
3、 Mastering the system, it is important to apply imported electrical appliances. These brands of components have outstanding performance in terms of application life and obstruction rate among similar products. Accepting these brands of components enables machinery to ensure customer application in terms of application life and precision temperature control.
4、 In terms of security protection, in addition to the usual reverse, media shortage, overload, relay jamming, PASS pressure relief, and other aspects; We also plan to have no pressure, no introduction, no heating, and when the temperature reaches the set upper limit, it will trip and power off for protection; In addition, mechanical control has increased the use of critical stop switches, electric heating selection switches, and active/manual exhaust functions (such as adding high-temperature exhaust valves), which greatly limits the application period of protective thermal oil.
5、 Only the one side through which the heat transfer oil passes is continuously covered with carbon steel hard pipes to prevent potential safety hazards such as oil leakage; The heating cylinder of the open water chiller receives foam glass hard insulation cotton, which is characterized by heat preservation, heat insulation and flame retardancy, increasing the electrical heating conversion rate of the machine, and creating greater costs for customers.
Our engineers report on how to safely apply open chillers:
When selecting an open chiller factory, it is necessary to pay attention to whether its products have the following effects in the safety protection plan:
1. The open type chiller system cannot start heating without pressure, which can prevent dry burning of the heating tube.
2. The atmosphere release function ensures that when the over temperature controller detects that the system temperature exceeds the planned temperature of the building, the release will disconnect the main power switch of the building, ensuring that the open type chiller will not get angry or become chaotic due to high temperature.
Refrigeration Encyclopedia